ASTM E119, CAN/ULC S101 – Fire-Resistance Rating
DATE OF TESTING: June 6, 2018
TESTED RATING: 2-Hour Fire Resistance
CAN/ULC-S102 – Flame Spread and Smoke Development
DATE OF TESTING: June 25, 2018
TESTED RATING: Flame Spread index = 0
TESTED RATING: Smoke Developed Index = 0
CAN/ULC-S135-04 – Non-Combustibility
DATE OF TESTING: March 6, 2017
TESTED RATING: Pass
ASTM E2357 – Air Leakage
DATE OF TESTING: September 14, 2018
RESULT: For each loading stage of the air pressure conditioning for geographical areas where pressure design value is Q10 > 0.20 kPa, there was observed to be no sign of fracture, delamination, loosening of fasteners or deleterious effects.
RESULT: Infiltration & Exfiltration @ 25-300PA <0.002 L/(s*m^2)
TESTED RATING: Pass
ASTM C426 – Linear Shrinkage
DATE OF TESTING: January, 2017
TESTED RATING: Pass
Hygrothermal testing and report
“The hygrothermal performance assessment for the Super SSR Modular Block Wall System comes to the conclusion that this system works without any additional vapor retarder.”
Please review the WUFI report by Manfred Kehrer in detail hereĀ JSS Hygrothermal Performance Report